| ★电气参数 | ★Electrical Parameters |
| 工作电压 | Operating Voltage |
| DC24-80V;AC20~55V | DC24-80V; AC20~55V |
| 信号电压 | Signal Voltage |
| 4.2~28V | 4.2~28V |
| 信号频率 | Signal Frequency |
| ≤150KHz | ≤150KHz |
| 信号接口 | Signal Interface |
| 控制方式 | Control Method |
| 共阴、共阳、差分 | Common Cathode, Common Anode, Differential |
| 触发方式 | Trigger Method |
| 上升沿触发,下降沿可改 | Rising Edge Trigger, Falling Edge Configurable |
| 工作模式 | Operating Mode |
| 单、双脉冲,速度10模式(需设定) | Single/Dual Pulse, Speed 10 Mode (Requires Setting) |
| SP01锁机电流可调,需调试工具 | SP01 Locking Current Adjustable, Requires Debug Tool |
| 参数设定 | Parameter Setting |
| SP05脉冲平滑可调,需调试工具 | SP05 Pulse Smoothing Adjustable, Requires Debug Tool |
| SP17电机电感量可调,需调试工具 | SP17 Motor Inductance Adjustable, Requires Debug Tool |
| 适配电机 | Compatible Motors |
| 57全系列,86系列12Nm以下电机 | 57 Full Series, 86 Series Motors Below 12Nm |
| 电机释放功能有效 | Motor Release Function Active |
| 其他设定 | Other Settings |
| 掉电相位记忆功能有效 | Power-Off Phase Memory Function Active |
| 欠压、过压报警 | Undervoltage, Overvoltage Alarm |
| 故障保护 | Fault Protection |
| 过流报警 | Overcurrent Alarm |
| 过热报警 | Overheat Alarm |
Precautions
The input voltage must not exceed DC 80V;
The input control signal level is 5-24V. When the host device uses 24V level, connecting a 1K resistor in series helps improve anti-interference capability;
The input pulse signal is active on the falling edge. For rising edge control, internal driver parameters need to be configured;
When the driver temperature exceeds 75°C, the driver stops working and the fault indicator ALM lights up. The driver must be powered on again to resume operation after the temperature drops to 50°C. If overheating protection is triggered, please install a heat sink;
If the overcurrent (load short-circuit) fault indicator ALM lights up, please check motor wiring and other short-circuit issues. After resolving the problem, power cycle the driver to restore operation;
If the no-motor fault indicator ALM lights up, please check motor wiring. After resolving the issue, power cycle the driver to restore operation.
| D6 | Self-test switch |
|---|---|
| OFF | External pulse |
| ON | At a speed of 30 rpm |
Note: 1. When D6 is ON, the self-test switch is OFF.
2. When D6 is OFF, the self-test switch is ON.
| D5 | Pulse Mode |
|---|---|
| ON | Dual Pulse: PU is the forward pulse stepping signal, DR is the reverse stepping pulse signal |
| OFF | Single Pulse: PU is the stepping pulse signal, DR is the direction control signal |